HomeHow is the load capacity of a single-phase current transformer defined?

How is the load capacity of a single-phase current transformer defined?

Publish Time: 2024-12-19
As an important measurement and protection device in the power system, the load capacity of a single-phase current transformer is a key performance indicator. It profoundly affects the working efficiency of the transformer and the normal operation of the secondary equipment connected to it.

The load capacity of a single-phase current transformer is usually defined by the rated load. The rated load refers to the maximum external load impedance value that can be connected to the secondary winding of the transformer while ensuring its accuracy and performance. This impedance value is generally expressed in ohms (Ω), for example, there are different specifications such as 5Ω and 10Ω. It covers the equivalent impedance of all devices connected to the secondary side, including ammeters, relays, energy meters, and the resistance and inductance of the connecting wires.

The load capacity of the transformer depends on its own design parameters. The characteristics of the core play a vital role. The magnetic permeability of the core determines its ability to conduct the magnetic flux generated by the primary current, which in turn affects the size of the induced electromotive force of the secondary winding. The turns ratio is also one of the key factors. A reasonable turns ratio design can generate a suitable induced current on the secondary side to drive the load equipment when different primary currents are input. For example, for a single-phase current transformer with a turns ratio of 100:5, when 100A current passes through the primary side, 5A current will be generated on the secondary side. At this time, if the secondary load impedance is too large and exceeds its rated load, the secondary current will decrease and the measurement accuracy will decrease.

Load capacity is also related to the operating frequency of the transformer. At the standard frequency of the power system (such as 50Hz or 60Hz), the transformer can work well within the rated load range. However, when the frequency changes, such as in some industrial environments with a large number of frequency conversion equipment, the impedance of the inductor and capacitor will change with the frequency, which may cause the actual load impedance to exceed the load capacity of the transformer, thereby affecting its performance.

When the connected secondary load impedance exceeds the rated load, a series of problems will arise. On the one hand, it will reduce the output current of the transformer, resulting in an increase in the measurement error, which will cause inaccurate measurement for electric energy measurement; for protection devices, it may cause them to malfunction or refuse to operate, seriously threatening the safe and stable operation of the power system. On the other hand, excessive load may also increase the heating of the transformer, accelerate insulation aging, and shorten its service life.

Therefore, in practical applications, it is necessary to accurately calculate and evaluate the load capacity of the single-phase current transformer, reasonably select matching secondary equipment and connecting wires, and ensure that the transformer works within the rated load range to give full play to its measurement and protection functions in the power system and ensure the safe and reliable operation of the power system.
×